Appliance running costs

Cost to run an air conditioner

An air conditioner does not draw its rated power continuously in most homes. This page applies that behaviour — cycling operation at 60% duty — and shows every step of the arithmetic.

How much does a 1,200 W air conditioner cost to run?

A 1,200 W air conditioner switched on 8 hours per day at 60% duty cycle uses 5.79 kWh of electricity per day. At $0.180/kWh that is $1.04 per day, about $31.73 per average month and $380.79 per year — 2,115 kWh over the year. Those figures assume a typical wattage and a typical usage pattern; change any input below to match your own appliance and tariff.

Your inputs

Typical example — replace this 1,200 W default with your appliance’s actual rating for a better estimate.

This appliance cycles — typical range around 60%.

Applies only to the 16 h a day the appliance is switched off, not to the idle part of the duty cycle.

Use the total variable rate from your bill, including delivery charges per kWh.

Scenario: hours per day

$31.73

per month (30.44-day average month)

5.79 kWh per day at 1,200 W

Estimate using typical assumptions
Per day
$1.04
kWh / month
176
kWh / year
2,115
Per year
$380.79

Average power across 24 hours

241 W

Daily energy spread evenly over 24 hours. Includes standby draw during switched-off hours when entered.

Cost per running hour

$0.130

While the appliance is actually drawing power.

Effective duty cycle

60%

Share of switched-on time at rated power.

Method

  1. 1,200 W = 1.2 kW
  2. 1.2 kW × 8 h/day × 60% duty = 5.76 kWh/day active
  3. 2 W standby × 16 h/day off = 0.032 kWh/day standby
  4. 5.76 + 0.032 = 5.792 kWh/day total
  5. 5.792 kWh × 0.18 USD/kWh = 1.043 USD/day
  6. 1.043 × 30.436875 days = 31.732 USD/month
  7. 5.792 kWh × 365.2425 days = 2115.485 kWh/year
  8. 2115.485 kWh × 0.18 USD/kWh = 380.787 USD/year

Monthly figures use a 30.44-day average month, 365.24-day average year.

Assumptions

  • Electricity rate of 0.18 USD/kWh (editable).
  • Calculations use a year of 365.2425 days and an average month of 365.2425 ÷ 12 = 30.436875 days, so twelve average months equal one year exactly. Displayed values are rounded to 365.24 and 30.44 days, and the rounded figures do not multiply out exactly.
  • Duty cycle of 60% — the appliance draws rated power for that share of the time it is switched on.
  • 2 W standby draw for the 16 hours a day the appliance is switched off. Standby applies only outside the switched-on hours, not to the idle part of the duty cycle, and is included in every kWh and cost figure below.
  • Rated power is treated as real power in watts, not volt-amps.

What can change the result?

  • Compressor duty cycle, which tracks outdoor temperature
  • Whether the unit is single-speed or inverter-driven
  • Thermostat setpoint and room insulation
  • Unit efficiency (EER/SEER) — the same cooling can need very different input power

$31.73/mo · 176 kWh/mo

How a air conditioner actually draws power

An air conditioner is a heat pump running in reverse, and its input power is not fixed. A single-speed unit cycles the compressor on and off — the fan keeps running, the compressor does not. An inverter unit instead modulates, drawing high power to pull the room down and then settling at a much lower steady draw. Input power also rises as outdoor temperature rises, because the machine has to reject heat against a hotter outside.

The duty cycle below matters more than the wattage. On a mild day a unit may run 30% of the time; during a heatwave it can approach 100%. Cooling capacity in BTU is not electrical power — divide BTU/h by the unit's EER to get watts drawn.

Cost at different usage patterns

All rows use 1,200 W at 60% duty and $0.180/kWh. Only the hours change.

Generated by the same energy engine that powers the calculator above.
Hours per daykWh per dayPer dayPer monthPer year
4 h/day2.92 kWh$0.53$16.00$191.97
6 h/day4.36 kWh$0.78$23.86$286.38
8 h/day5.79 kWh$1.04$31.73$380.79
12 h/day8.66 kWh$1.56$47.47$569.60

Cost across the typical wattage range

Units in this category typically range from 500 W to 3,500 W. All rows use 8 h/day at 60% duty.

Source for the range: Typical input power of window and small split air conditioners (2026-01).
Power ratingkWh per dayPer dayPer monthPer year
500 W2.43 kWh$0.44$13.32$159.89
1,200 W5.79 kWh$1.04$31.73$380.79
3,500 W16.8 kWh$3.03$92.22$1,107

Worth knowing

BTU rating describes cooling output, not electricity input.

Worth knowing

Compressor start draws a brief surge well above running watts, which matters for battery backup and generator sizing.

Your next decision

Your next decision